hiclover medical incinerators whole view
By : Admin -
                                Principle of the Incinerator equipment is incineration/combustion/burn. Generally, the function is waste treatment for Solid waste, Liquid waste, Gas waste, etc.
The main body is one combustion chamber (at least), Refractory line or firebrick, Insulation materials and the outer plate. Ignition element is external oil or gas burner. The burner can be running until waste burnout but for some waste like plastic, paper (sometime, mix coal with waste before feeding), they can combustion itself after Ignition. During combustion, burner has a fan itself for Oxygen supply and also protect burner avoid heat damage from combustion chamber. And, there a external fan blow air into combustion chamber. The Exhaust gas blow out after combustion.
Tel: +86-25-8461 0201
Website: www.hiclover.com
Email: sales@hiclover.com
Email: hicloversales@gmail.com
| Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) | 
| Burn Rate (Average) | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour | 
| Feed Capacity(Average) | 20kg | 40kg | 60kg | 100kg | 200 kg | 
| Control Mode | PLC | PLC | PLC | PLC | PLC | 
| Combustion Chamber | 100L | 210L | 330L | 560L | 1200L | 
| Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm | 
| Secondary Chamber | 50L | 110L | 180L | 280L | 600L | 
| Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes | 
| Feed Mode | Manual | Manual | Manual | Manual | Manual | 
| Voltage | 220V | 220V | 220V | 220V | 220V | 
| Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw | 
| Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 | 
| Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 | 
| Temperature Monitor | Yes | Yes | Yes | Yes | Yes | 
| Temperature Protection | Yes | Yes | Yes | Yes | Yes | 
| Oil Tank | 100L | 100L | 100L | 100L | 200L | 
| Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm | 
| Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter | 
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | 
| 1st. Chamber Temperature | 800℃–1000℃ | 800℃–1000℃ | 800℃–1000℃ | 800℃–1000℃ | 800℃–1000℃ | 
| 2nd. Chamber Temperature | 1000℃-1200℃ | 1000℃-1200℃ | 1000℃-1200℃ | 1000℃-1200℃ | 1000℃-1200℃ | 
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 
| Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg | 
| External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm | 
Primary and secondary burners: Separate electrically spark-ignited primary burners and secondary burners with automatic control shall be used to achieve the specified temperature requirements in the primary and secondary chambers. The flames  of the primary and secondary burners shall not impinge on the incinerator walls or floor.
Energy source for burners Diesel fuel eil
Air supply: Air supply in the primary and secondary chamber should be regulated between 30%-80% and 170%- 120% of stoichiometric amount respectively. Suitable flow measurement devices shall be provided on the primary and secondary air ducting. The combustion air shall be supplied through a separate forced draft fan after accounting for the air supplied through burners
lnsulation: lnsulation to be used for masonry, reinforced concrete, or non-combustible material shall prevent damage to the foundation from excessive heat and shall be of a thickness to limit the outer casing to a maximum temperature of 66°C in an ambient temperature of 21°C when the incinerator is operating at full capacity.
Refractory: Refractory shall be #super duty# and heat-resistant to a minimum of 1100°C in the primary chamber and 1250°C in the secondary chamber. Refractory shall also be abrasion resistant in the prlmary chamber, constructed of plastic or castable type refractory, designed to prevent bulging and destruction due to heat stress, capable of supporting more than twice the hourly burning rate and preventing leakage of fluids, and with a minimum thickness of 11O mm for walls and hearths
Electrical 220V, single phase, 50Hz electrical power
Electrical safety: The medical waste incinerator shall meet the requirements of  IEC
61010-2-040, UL 61010A-2-041, or an equivalent electrical safety standard; as weil as the electromagnetic compatibility requirements under EN 61326:1997 or equivalent standard.
Physical: Safety	Belts, pulleys, chains, gears and other rotating parts as well as sharp edges, located where persons come in close proximity to them, shall be enclosed or guarded
to protect personnel. High-temperature surfaces and piping located where they could endanger personnel or create a fire hazard shall be covered with insulation
Noise level The noise level at 305 mm from any incinerator component shall not exceed 85 dBA.